Skip to content

IMU data reads #21

Description

@alanbithell

In your function dmpDataReady, instead of setting IMUdataReady = 1, try incrementing the value, then in your main loop, read the data IMUdataReady times to clear the FIFO and decrement that counter with each loop.
This will prevent fifo overflow and give you the most recent value from the IMU.
I would have added this to code and created a PR but part 19 isn't up.

void dmpDataReady() {
    IMUdataReady++;
}

...main loop...

// IMU test
while (IMUdataReady > 0) {
    readAngles();
    IMUdataRead--;
}